草榴社区

Precision Light Scatter Data for
Faster, More Cost-Effective Optical Product Development

??? ?? 草榴社区? ?? ? ?? ???? ???? ???? ?? ??? ?? ??? ??? ??? ????

??? ? ??, ?? ? ?? ??? ?? ???

草榴社区 TIS Pro


草榴社区 TIS Pro? ???, ??? ? ???? ????? ???? ?? ?? ?? ?? ?????. ? ?? ???? ??? ??? ??? ?? ??? ???? ?? ??? ???? ?????? ??? ?? ?? ? ???? ???? ???? ???.

草榴社区 TIS Pro? ??? ??? ??? ??? ???? ??? ????? ?? ?? ????? ?? ???? ?????.

SmartStart ?????  | 草榴社区

??? BSDF (?? ??) ??? ??

SmartStart Library


草榴社区 ? LightToolsLucidShape ??? ??? ??? ???? ?? ??? ??? ? ??? ??? ?? ??? ??? ????? ???? ??? ? ?? ???? ?????. ? ?? ?? ??? ??? ??? ?? ??? ?? ? ?? ???? ?? ?? ???? ???? ?? SmartStart ?????? ????? ???? ?? ????.

SmartStart ?? ??? | 草榴社区

? ?? ?? ???

SmartStart Measurement Service


?? ??? ?? ?? ???? ??????? ??? ?? ???? ??? ?? ??? ???? ?? ?? ??? ?????. ??? ?? ????? ??? ?? SmartStart ?? ???? ?????.

  • 2D ? 3D BSDF(?? ? ??) ??

  • ???? BSDF

  • ???? BSDF 

  • ?? ?? ???(TIR) ??

  • ? ?? ??(TIS) ??

  • UV, ???? ? IR ??(280 nm~10.6 microns)


?? ??? ?? ??? ?? ?? ??? | 草榴社区

?? ??? ?? ??? ?? ?? ???

High Specular Bench


草榴社区? High Specular Bench? ?? ??? ?? ? ??? ?? ?,?? ? ?? ???? ?? ?????. ? ???? 2D ???? ???? ?? ?? ??? ????? ??? ???? ???? BRDF ? BTDF? ?????.

?? ?? ?? ?? ???? ?? ??? High Specular Bench? ??? ??? (3.39 ? 10.6 ?m)?? ???????. ?? 280nm? ??? ???? 1013 ? ?? ??? 10.6?m? ??? ????? ?? ?? ???? ??? ? ???? .

High Specular Bench? 10?? ??? ?? ?????? ?? 0.02°? ???? ?????.

High Specular Benchs? ?? ??? ???? ???? ???? ???? ????.  

?? ??? ?? ?? ??

Mini-Diff V2


Mini-Diff V2? ? ?? ??? ???? ?? ?? ??? ??????. ?? ??? ??? ??? BRDF ? BTDF? ??? ? ????. Mini-Diff V2? ???, ??, ?? ? ???? ???? ??? ??? ??? ???? ???? ???? ?????.

Mini-Diff V2? Calibration ?? ??, ????? ? ???? ??? ?? ???? ?? ?????.

??? 2D/3D ?? ?? ??? ??? ?? ??

Mini-Diff VPro


Mini-Diff VPro? ??? ??? 3D ??? ?? ?? ?????. Mini-Diff V2? ????? Mini-Diff VPro? BRDF, BTDF ? TIS ??? ???? ??, ??? ? ??? ???? ?????.

Mini-Diff VPro? ??? ??? ?? ??? ???? ?? ? ?? ? ?? ??? ???? ?? ??? ???? ???? ?????. ? ??? ?? ? 0°?? 60°?? ??? ?? ???? ??? ? ??? Mini-Diff ?? ?????? ?? ?? ? ?????.

??? ?? ?? ???

REFLET 180S


REFLET 180S? 3D ???? ???? ?? ?? ?? ??? ???? ??? ???? BRDF ? BTDF? ???? ?? spot? ?? ??? ??? ????? ??? ?????. REFLET 180S? ?? ??? ?? ? ??? ?? ?, ?? ? ?? ???? ?? ?????. ?? ?? ??? ??? ??? ??? ? ??? ? ?? ?? ? ??? ???? ???? ??? ? ????. 

Videos and Blog Articles

?? ? ???

Equipment Specification Chart

?? ?? ???

 Mini-Diff V2Mini-Diff VProREFLET 180SHigh Specular
Measurement of Light Scattering
(????)
ARS/BRDF/BTDFARS, BRDF and BTDFARS/BRDF/BTDFARS/BRDF/BTDF
Wavelength Light Source
(??? ??)
465 - 525 - 630 nm - 850 nm and 940 nm 465 nm, 525 nm and 630 nm Halogen white lamp + passband filter Discrete values from 280 nm to 10.6 ?m
Wavelength Detector Sensitivity
(??? ?? ?? ??)
NANA Visible
Infrared 900-1700 nm
Optional Spectrometer [400-800] nm
NA
Angles of Incidence
(?? ?? ??)
Fixed for BRDF and BTDF: 0°, 20°, 40° and 60° Tunable:
For BRDF and BTDF: from 0° to +60°
Tunable:
For BRDF and BTDF: from 0° to +90°
Tunable:
For BRDF: from 5° to +90°
For BTDF: From 0° to +90°
Angular Range
(?? ?? ??)
3D spherical measurement3D spherical measurement2D and 3D spherical measurement2D spherical measurement
Spot Size (diameter)
(?? ??)
> 1 mm > 1 mm 1 mm to 13 mm continuous 2 mm to 14 mm depending on wavelengths
Observed Area Size
(?? ?? ??)
? 1 mm ? 1 mm ? 6 mm /? 8 mm /? 14 mm NA
Beam Divergence
(? ?? ??)
NANA+/- 2.26° to +/- 0.15° +/- 0.01° for visible +/-0.1° for infrared
Incident Beam Positioning Precision
(?? ?? ?? ???)
NANA0.001° +/- 0.001°
Detector Acceptance Angle
(?? ?? ??)
+/- 0.5° +/- 0.5° +/- 0.04° / 1.1° / 2°+/- 0.001°
Detector Positioning Precision
(?? ?? ???)
NANA0.001°NA
Measurement Resolution
(?? ???)
0.01°/0.1°/1°/10°0.001°
Global Axes Alignment
(?? ? ??)
< 0.5°0.002°
Accuracy
(???)
< 5%< 2%< 1%< 1%
Repeatability
(???)
< 2%< 2%< 1%< 1%
Minimum BRDF
(?? BRDF)
10e-210e-3< 10e-4 < 10e-7 (10e-5 for infrared)
Dynamic Range
(?? ??)
10e510e6 for BTDF
10e5 for BRDF
10e9 for visible and 10e6 for infrared 10e13 for visible and 10e9 for infrared
Minimum Signature
(?? ?? ??)
+/- 1° for BTDF at 0° at 525 nm +/- 0.5° for BTDF at 0° at 525 nm +/- 0.15° +/- 0.01° for visible and +/- 0.1° for infrared
Weight
(??)
2 kg 42 kg 80 kgNA
Dimensions
(??)
10 x 10 x 30 cm 450 mm x 600 mm x 738 mm86 x 98 x 122 cmNA
Advantages
(???)
Plug and play
Easy to use and fast
Portable and compact
Affordable
High precision
High stability
Easy-to-use instrument
Laboratory version of the Mini-Diff V2
High dynamic range
High precision
High repeatability
Customizable wavelength range
Very high dynamic range
Measurement at 0.02° from the specular
High precision
High repeatability
Customizable wavelength range

Our Scattering Measurement Instruments Are Used by Industry-Leading Companies

草榴社区? ?? ??? ???? ???

  • Automotive Lighting
  • BARCO
  • Bayer
  • Bosch
  • Broadcom
  • CREE
  • ESA

  • Nikon
  • Osram
  • Philips
  • Thales
  • VARROC
  • Sordern
  • Visteon